Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Braz. J. Pharm. Sci. (Online) ; 58: e20123, 2022. tab, graf
Article in English | LILACS | ID: biblio-1403715

ABSTRACT

Abstract In this study, microemulsions containing etofenamate were prepared and evaluated as dermal delivery carriers. The developed microemulsions consist of oleic acid, Span 80, Tween 20, Cremophor EL, Transcutol and ethanol. The percentage of etofenamate loading in the microemulsions was 5% (w/w). The characterization of formulations included droplet size, zeta potential, pH, conductivity, PDI, refractive index and viscosity. Moreover, ex vivo penetration study was carried out using mice abdominal skin. The developed formulations were analyzed for their cytotoxicity via MTT assay and tested for their anti-inflammatory properties opposed to LPS-stimulated nitrite prοduction in RAW 264.7 cells. As ideal formulation, M2ETF, was chosen due to its greater permeation, lower penetration as well as higher anti-inflammatory


Subject(s)
Osteoarthritis/pathology , Polysorbates , Refractometry/methods , Skin , Anti-Inflammatory Agents, Non-Steroidal/adverse effects , RAW 264.7 Cells/classification , Hydrogen-Ion Concentration
2.
Rev. bras. oftalmol ; 80(1): 27-32, jan.-fev. 2021. tab
Article in Portuguese | LILACS | ID: biblio-1251323

ABSTRACT

RESUMO Objetivos: Avaliar a sensibilidade, especificidade e acurácia da refratometria obtida através do aparelho photoscreener 2WIN® como método de rastreio de ametropias com indicação de prescrição de óculos pelos critérios da Sociedade Brasileira de Oftalmopediatria em crianças assintomáticas, de origem extra-hospitalar, de 6 a 36 meses de idade, e determinar se a cicloplegia influencia a capacidade de rastreio do aparelho. Métodos: Cento e setenta e oito (178) de crianças com idades entre 6 e 36 meses tiveram sua refratometria mensurada pelo método padrão-ouro, a retinoscopia manual sob cicloplegia, e pelo método em teste, o photoscreener 2WIN®, antes e após a cicloplegia. Resultados: O photoscreener 2WIN® é capaz de identificar aqueles pacientes que deveriam receber prescrição de óculos pelos critérios da Sociedade Brasileira de Oftalmopediatria com sensibilidade de 100%, especificidade de 93,18% e acurácia de 93,26%, quando comparado a retinoscopia estática. Sob cicloplegia, o 2WIN® mantém sensibilidade de 100%, porém aumenta sua especificidade para 96,59% e a acurácia para 96,63%. Conclusão: O photoscreener 2WIN® se mostrou altamente sensível, específico e acurado para uso como equipamento de triagem daqueles pacientes de 6 a 36 meses que se beneficiariam do uso de óculos pelos critérios da Sociedade Brasileira de Oftalmopediatria, com discreto aumento da especificidade e acurácia quando aplicado em pacientes cicloplegiados.


ABSTRACT Objective: Evaluate the sensitivity, specificity e accuracy of the ocular refraction measured by the 2WIN® photoscreener as a screening method to identify children in need of spectacles prescription according to the criteria published by the Brazilian Society of Pediatric Ophthalmology (BSPO) in asymptomatic children, 6 to 36 months old, and determine the impact of cycloplegia in the sensitivity, specificity and accuracy of this method. Methods: One hundred seventy-eight (178) eyes of asymptomatic children between the ages of 6 and 36 months have been submitted to ocular refraction measurements by the gold-standard method, the manual retinoscopy under cycloplegia, and the method been tested, the 2WIN® photoscreening, both before and under cycloplegia. Results: The 2WIN® photoscreener before cycloplegia was able to identify those patients in need of spectacles prescription according to the criteria published by the BSPO with 100% sensitivity, 93.18% specificity and 93.26% accuracy, when compared to the manual retinoscopy under cycloplegia. The 2WIN® photoscreener under cycloplegia maintained a sensitivity of 100%, but increased specificity to 96.59% and accuracy to 96.63%. Conclusion: The 2WIN® photoscreener before cycloplegia showed high sensitivity, specificity, and accuracy in detection of patients in need of spectacles prescription according to the criteria published by the BSPO in the tested population, with minor increase in specificity and accuracy when the measurements were performed under cycloplegia.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Refraction, Ocular , Refractive Errors/diagnosis , Refractometry/methods , Retinoscopy/methods , Eyeglasses , Cross-Sectional Studies , Sensitivity and Specificity , Observational Study , Data Accuracy
3.
Acta amaz ; 47(1): 83-86, jan. -mar. 2017. tab
Article in English | LILACS, VETINDEX | ID: biblio-1455329

ABSTRACT

Total serum protein is a significant indicator of health condition in animals. The aim of this study was to analyze the precision of the portable refractometer in determining the concentration of total serum proteins in Podocnemis expansa and Phrynops geoffroanus. A total of 26 animals were used. The blood samples were collected from the supraoccipital sinus and stored in tubes without anticoagulant. Total serum protein was determined using both the biuret reaction and refractometry. The total serum protein mean concentration (g dL-1) with biuret method and refractometry for P. expansa were 3.16 and 3.2; and for P. geoffroanus were 3.56 and 2.72, respectively. These results indicate that total serum protein values can be determined with precision in P. expansa and P. geoffroanus using a portable refractometer.


A proteína sérica total é um indicador significativo do estado de saúde em animais. O objetivo desse estudo foi analisar a precisão do refratômetro portátil para determinar a concentração de proteínas séricas totais em Podocnemis expansa e Phrynops geoffroanus. Foram utilizados um total de 26 animais. As amostras de sangue foram coletadas por punção do seio supraoccipital e armazenadas em tubos sem anticoagulante. A concentração de proteína sérica total foi determinada utilizando tanto a reação de biureto como um refratômetro portátil. A média da proteína sérica total (g dL-1) pela reação de biureto e pela refratometria para P. expansa foram de 3,16 e 3,2; e para P. geoffroanus foram de 3,56 e 2,72, respectivamente. Estes resultados indicam que os valores de proteínas séricas totais podem ser determinados com precisão em P. expansa e P. geoffroanus usando o refratômetro portátil.


Subject(s)
Animals , Blood Proteins/analysis , Biuret Reaction/methods , Refractometry/methods , Turtles/blood , Methods
4.
Rev. cuba. farm ; 44(4): 476-484, oct.-dic. 2010.
Article in Spanish | LILACS | ID: lil-584551

ABSTRACT

La calificación de los diferentes componentes del sistema HPLC es un aspecto de vital importancia para el logro de buenos resultados en la validación de un método analítico, pues se necesita demostrar previamente que el sistema se encuentra trabajando de forma satisfactoria. En este caso la evaluación reviste una gran importancia, por tratarse de instrumentos de varios años de uso, con los que el fabricante no se responsabiliza, por lo que se recopiló información de instrumentos similares producidos por otros fabricantes o establecidos para versiones modernas de estos donde se describiera la forma de evaluar los parámetros más importantes en el funcionamiento de cada uno de los componentes del sistema cromatográfico a usar. Para calificar la bomba isocrática (Pharmacia-LKB), se evaluó la función de bombeo, la indicación del cero de presión, el límite mínimo y máximo de presión, así como la prueba de hermeticidad y la exactitud del flujo. Para calificar el detector de índice de refracción (Knauer), se evaluó la señal de ruido, la sensibilidad y la linealidad de la señal. Además se calculó la precisión del inyector. Se determinó que tanto la bomba isocrática como el detector de índice de refracción y el inyector manual cumplen con todos los parámetros estudiados, lo que demuestra que todos los componentes del sistema de HPLC cumplen con las especificaciones establecidas y adecuadas a sus características, además de satisfacer los requerimientos necesarios para la determinación de impurezas mediante esta tecnología


The assessment of different components of HPLC system is a very important feature to achieve good results in validaion of a analytical method since it is necessary to demonstrate previously that this system is working in a satisfactory way. In present case the assessment is very important to be about of instruments of some years of use where the manufacturer not accept responsability for the information collected on similar instruments produced by other manufacturers for current versions of these where is is described the way to assess the more significant parameters in the functioning of each components of chromatographic system to be used. To assess the isocratic pump (Pharmacia-LKB) pumping function, zero-pressure indication, minimal and maximal pressure limit, as well as the sealed test and flow accuracy. To determine the refraction rate detector (Knauer), the noise, sensitivity and linearity signal was assessed. Also, the injector's accuracy was estimated. Authors determined that the isocratic pump as refraction rate detector and the manual injector flufill with all study parameters demonstrating that all components of HPLC system also fulfill with specifications established and suitable to its features, satisfying the requirements necessaries for determination on impurities using this technology


Subject(s)
Quality Control , Chromatography, High Pressure Liquid/instrumentation , Chromatography, High Pressure Liquid/trends , Refractometry/methods
5.
Pesqui. vet. bras ; 30(8): 670-675, ago. 2010. graf, mapas, tab
Article in Portuguese | LILACS | ID: lil-559902

ABSTRACT

O perfil hematológico sanguíneo foi determinado em três populações de Ctenomys lami, em áreas denominadas A e B, impactadas pela bovinocultura, e C, sem impacto antrópico, ambas no sul do Brasil. Sessenta e dois animais foram coletados ao total. Os valores de hematócrito (Ht), hemoglobina (Hb) e eritrócitos apresentaram diferenças significativas entre machos e fêmeas. Os valores médios de Ht e a Hb encontrados na espécie foram mais baixos em comparação com os de outras espécies de roedores subterrâneos, podendo estes valores estarem relacionados ao habitat de forrageio ou às características do solo. Também foram encontradas diferenças significativas nas médias de hemoglobina, CHCM e linfócitos em animais das áreas A e B em relação à área C. O valor da média dos hematócritos dos animais entre as áreas foi mais elevado nas áreas A e B, porém significativamente diferentes entre A e C. Algumas dessas alterações sugerem a relação dos valores encontrados com o estresse dos animais em relação a áreas impactadas. Variações significativas no VCM foram encontradas entre os animais das áreas A e C, e também nas plaquetas destes entre as áreas A e B. Não foram observados Corpúsculo de Kurloff no sangue dos animais analisados. Os valores hematológicos encontrados nesses espécimes de Ctenomys lami fornecem informações importantes sobre a espécie e podem ser úteis em outras pesquisas.


The hematological profile was determined in three populations of Ctenomys lami that inhabits three different areas nominated as A and B, affected by cattle production, and C, without human impact, all of them in southern Brazil, under the same geologic formation. Sixty two individuals were collected. The packed cell volume (PCV) values, hemoglobin (Hb) and red blood cell (RBC) count presents statistic significant differences between males and females. PCV and Hb values were lower in comparison with other subterranean rodents, which could be related to the food searching behavior or soil characteristic of the species. Significant statistic differences were found to for Hb, mean corpuscular hemoglobin concentration (MCHC) and lymphocytes between animals belonging to A and C areas. The PCV values were higher for animals from areas A and B, with significance only between A and C. Some of these alterations may suggest a modification on stress levels of the animals inhabiting areas A and B with anthropic alterations, or maybe just an inherited characteristic. Significant statistic differences were found either in mean corpuscular volume (MCV) between A and C areas, and platelets between A and B areas. No Kurloff cells were observed in the blood smear from analyzed individuals. The hematological values founded for Ctenomys lami are an important information for this species, which can be used for future research and management.


Subject(s)
Animals , Male , Female , Blood Physiological Phenomena , Refractometry/methods , Refractometry/veterinary , Rodentia/blood , Biopsy, Needle , Genetics, Behavioral , Staining and Labeling
6.
Pesqui. vet. bras ; 29(6): 457-460, jun. 2009. graf, tab
Article in Portuguese | LILACS | ID: lil-525666

ABSTRACT

As serpentes peçonhentas dos gêneros Bothrops e Crotalus têm sido mantidas em cativeiro visando à extração de venenos para a produção de imunobiológicos. O conhecimento da fisiologia desses animais e as alterações na concentração de proteínas e suas frações séricas são importantes para a identificação precoce de importantes enfermidades que cursam com estados de hipoproteinemia e hiperproteinemia. O objetivo do trabalho foi determinar a concentração de proteína total e o perfil eletroforético das proteínas séricas de serpentes Crotalus durissus terrificus (cascavel) criadas em cativeiro. Foram colhidas amostras de sangue da veia coccígea ventral de 21 serpentes adultas e sadias, divididas em dois grupos: Grupo 1 de 12 machos com peso médio de 588,89±193,55g, e Grupo 2 de nove fêmeas com peso médio de 708,33±194,04g. A proteína total sérica foi determinada pelo método de refratometria e a eletroforese em gel de agarose. Obtiveram-se valores da proteína total sérica (g/dL) de 4,51±0,50 para machos e de 4,82±0,72 para fêmeas, e para machos e fêmeas de 4,64±0,61. Foram identificadas pela eletroforese quatro frações protéicas (g/dL): albumina, a, b, g-globulinas e calculada a relação albumina:globulina. As serpentes fêmeas apresentaram maiores valores para as variáveis, albumina e para a relação albumina/globulina (AG) diferindo significativamente (P<0,05) do grupo de machos, porém sem significado clínico.


The poisonous snakes of the genera Crotalus and Bothrops have been kept in captivity with the purpose of extracting poison for the production of immunobiological. Knowledge of the physiology of these animals and serum proteins concentration changes are important for early identification of major diseases which lead to states of hypoproteinemia and hyperproteinemia. The objective was to determine the concentration of total protein and serum protein electrophoresis profile of Crotalus durissus terrificus (rattlesnake) in captivity. Blood samples were taken from the ventral coccygeal vein of 21 adult and healthy snakes divided into groups: Group 1 with 12 males, weighing in average 588.89±193.55g, and Group 2 with nine females, weighing in average 708.33±194.04g. The total serum concentration of protein was determined by the method of refractometry and agarose gel electrophoresis. The total protein values in the serum for females was 4.82±0.72, for males 4.51±0.50 and males and females 4.64±0.61, identified by four fractions (g/dL): albumin, a, b and g-globulin. Additionally the albumin/globulin ratio was calculated. The female snakes showed higher values for the variables, albumin and the albumin/globulin (AG) differed significantly (P<0.05) from the group of male snakes, but there was no clinical significance.


Subject(s)
Animals , Male , Female , Albumins , Alpha-Globulins , Beta-Globulins , Crotalus , gamma-Globulins , Refractometry/methods , Blood Protein Electrophoresis/methods , Electrophoresis, Agar Gel/methods
7.
Arq. bras. oftalmol ; 70(1): 67-72, jan.-fev. 2007. ilus
Article in Portuguese | LILACS | ID: lil-453131

ABSTRACT

OBJETIVO: Lentes de contato gelatinosas com curvas-base esféricas têm sido usadas há anos. O cálculo do poder refrativo de lentes deste tipo é fácil, bastando utilizarmos a equação do fabricante de lentes para lentes espessas. No entanto, para projetos de lentes de contato personalizadas, não há ainda métodos confiáveis para medida das aberrações ópticas de ordem mais alta. Esse trabalho foi desenvolvido no laboratório do Centro de Ciências da Visão (Center for Visual Science) da Universidade de Rochester, Nova York, com aparelho óptico que permite realizar medidas precisas de aberrações de ordem baixa e alta de lentes de contato gelatinosas personalizadas. Este é um passo essencial na verificação e obtenção de lentes de contato personalizadas de qualidade, e o instrumento desenvolvido na Universidade de Rochester permite verificar a qualidade de fabricação destas lentes. MÉTODOS: Um aparelho óptico de bancada foi montado em laboratório. Este aparelho consiste de uma célula úmida onde as lentes de contato são depositadas. Consiste também de uma série de lentes e espelhos e um sensor de frente-de-onda de Hartmann-Shack. As lentes de contato personalizadas utilizadas neste projeto foram fabricadas pela empresa Bausch & Lomb. Das dezenas de lentes de contato mensuradas no aparelho, restringimos aqui a apresentar os resultados de uma lente personalizada para ceratocone. RESULTADOS: O erro quadrático médio (EQM) do instrumento foi de 0,04 micrômetro, sendo que o EQM das aberrações induzidas na lente está entre 4 e 6 micrômetros, ou seja, a precisão do aparelho está em torno de 1 por cento. Este valor é mais do que suficiente para medidas precisas destes tipos de lentes de contato, algo até então inviável utilizando-se os sensores ou aparelhos convencionais de aberrometria. CONCLUSÃO: Com o instrumento desenvolvido neste trabalho foi possível realizar medidas precisas de aberrações de alta ordem. Esta tecnologia é importante para o desenvolvimento...


PURPOSE: Soft contact lenses with spherical base curves have been used for many years. The computation of the refractive powers of these lenses is easy, requiring only that one uses the lens maker equation for thick lenses. Nevertheless, for customized contact lenses, there is yet no reliable method for measuring the higher order optical aberrations. In this study we have developed in the Center for Visual Sciences of the University of Rochester an optical apparatus that allows for precise measurement of low and high order aberrations of customized soft contact lenses. METHODS: An optical apparatus was mounted on a conventional optical bench. This apparatus consists of a wet cell where the contact lenses are placed, a series of relay lenses, mirrors, beam splitters, and a Hartmann-Shack sensor. Bausch & Lomb manufactured the lenses used in this study. RESULTS: The root mean square error (RMSE) of the instrument was 0.04 microns. Given that the RMSE of the customized lens is between 4 and 6 microns, i.e., the precision of the instrument is approximately 1 percent. This precision is more than sufficient for the type of measurements necessary for manufacturing customized contact lenses. CONCLUSION: The instrument developed is extremely precise for measuring high order aberrations - up to the 10th order Zernike polynomials, that is, up to the 66th term. This technology is important for the development of new methods of optical corrections for patients that usually do not adapt to normal sphere-cylinder spectacles or that cannot undergo refractive surgery, such as those which have keratoconus, for example.


Subject(s)
Humans , Contact Lenses, Hydrophilic , Equipment Failure Analysis/methods , Image Enhancement/instrumentation , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Refractometry/instrumentation , Equipment Design , Refractometry/methods
9.
Rev. mex. oftalmol ; 69(1): 27-30, ene.-feb. 1995. ilus, tab
Article in Spanish | LILACS | ID: lil-188177

ABSTRACT

Se estudia la evolución de las medidas refractométricas en 44 ojos de 23 pacientes que fueron sometidos a queratotomía radiada. Se practicó refracción en las semanas uno, dos, cuatro, ocho y al año se compararon. Se encontró que si bien no había cambios si se consideraba a todo el grupo en general, sí existían variaciones en casos particulares, que disminuyeron en frecuencia y magnitud según pasa el tiempo. Hubo cambios mayores de una dioptría hacia la miopía, comparando con la medida al año, en 27 por ciento en la primera semana, 23 por ciento en la segunda, 16 por ciento en la cuarta y 11 por ciento en la octava. No se pudieron determinar factores que condicionen mayor cambio durante este tiempo. Se concluye que se debe ser cauto en la indicación de las reoperaciones en virtud de la frecuencia y magnitud de los cambios. Se hace énfasis en la necesidad de más estudios en el comportamiento de las reoperaciones.


Subject(s)
Adult , Middle Aged , Humans , Male , Female , Ophthalmologic Surgical Procedures , Visual Fields/physiology , Visual Field Tests , Myopia/therapy , Visual Perception/physiology , Keratotomy, Radial/methods , Refractometry/methods
10.
Arch. chil. oftalmol ; 52(2): 115-20, 1995. tab
Article in Spanish | LILACS | ID: lil-195226

ABSTRACT

En un grupo de 108 ojos de 55 niños se comparan los valores refractivos obtenidos a través de una autorrefractometría con y sin cicloplejía y una retinoscopia ciclopléjica. Se comprueba que las mediciones se correlacionan adecuadamente entre sí para todos los parámetros estudiados a excepción del eje del astigmatismo que sólo es similar entre la autorrefractometría y la retinoscopía ciclopléjica. Las correlaciones más fuertes se dan claramente entre la retinoscopía y la autorrefractometría con cicloplejía. El porcentaje de mediciones consideradas clínicamente inaceptables es mayor cuando la autorrefractometría es hecha sin cicloplejia especialmente por variaciones en el valor de la esfera. La existencia o no de ambliopía, la edad y el tipo de ametropía no fueron variables que determinaron un mayor número de mediciones inaceptables en la autorrefractometría. Los pacientes que fueron sometidos a prueba subjetiva tuvieron tendencia a preferir los valores medidos por la retinoscopía por sobre los de la refractometría automatizada con cicloplejia


Subject(s)
Humans , Male , Female , Child, Preschool , Adolescent , Refractometry/methods , Amblyopia/diagnosis , Eye Diseases/diagnosis , Hyperopia/diagnosis , Mydriatics/administration & dosage , Myopia/diagnosis , Ophthalmoscopy , Refraction, Ocular
11.
Arch. chil. oftalmol ; 51(2): 31-8, 1994. ilus, tab
Article in Spanish | LILACS | ID: lil-164825

ABSTRACT

Con el fin de establecer la confiabilidad de la técnica se realizó un estudio prospectivo de refracción automatizada durante un período de 12 meses en diversos centros de atención clínica logrando refraccionar objetivamente 7000 pacientes. El rango de edades fluctuó entre los 6 a los 94 años con una media de 66.3 años de los cuales el 42,7 por ciento fue de sexo masculino y el 57,3 por ciento de sexo femenino. Las ametropías más frecuentes fueron la hipermetropía y el astigmatismo miópico compuesto. El componente esférico resultó altamente confiable (76,3 por ciento), no así el componente cilíndrico (23,7 por ciento) que debe ser interpretado cuidadosamente. La refracción expresada en términos de componente cilíndrico negativo es mejor tolerada que en valores positivos cuando es a favor de la regla (86,7 por ciento). La confiabilidad de la variación esférica por sobre o bajo el promedio fue de 0,25 dioptrías (71,1 por ciento), en cambio la variación cilíndrica resultó más segura al disminuirla en 0,5 dioptrías (52,3 por ciento). El rendimiento de la técnica es mejor en edades entre los 20 a los 60 años (67,8 por ciento). Las mujeres manifestaron mayor tolerancia con la prescripción (76,3 por ciento). La confiabilidad según el eje del astigmatismo es ligeramente mejor cuando es a favor de la regla (36,9 por ciento). Diversas patologías, entre ellas diabetes y cataratas, son las que más errores causan durante la medición y la falta de discriminación entre un astigmatismo corneal o residual es el error más frecuente en la interpretación. La sensación de desnivel fue la causa más frecuente de intolerancia con la prescripción (11,3 por ciento). Finalmente la confiabilidad de la técnica fue de 97,4 por ciento


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Refractometry/methods , Technology , Astigmatism/diagnosis , Diagnostic Errors , Refractive Errors/diagnosis , Lenses/statistics & numerical data , Prospective Studies , Refractometry/statistics & numerical data , Refractometry/instrumentation , Patient Satisfaction/statistics & numerical data , Visual Acuity
12.
Alexandria Journal of Pharmaceutical Sciences. 1994; 8 (1): 1-10
in English | IMEMR | ID: emr-31552

ABSTRACT

The effect of substitution pattern on the polarity of flavonoid aglycones and the relation between the Rf value and structure of these compounds have been assessed


Subject(s)
Refractometry/methods
13.
Zagazig Medical Association Journal. 1993; 6 (2): 323-341
in English | IMEMR | ID: emr-31353

ABSTRACT

Thirty emmetropic subjects [50 eyes] and one hundred thirty myopic patients [260 eyes] were selected and examined ophthalmologically and by ultrasonic biometer. These myopic patients were classified into three groups [mild, moderate and high] according to the degree of myopia. Among the biometric measurement it was found that the mean axial length showed gradual persistent significant increase from 23.34 +/- 0.58 in emmetropes to 24.2 +/- 1.02 in mild myopia to 25.06 +/- 0.77 in moderate myopia then to 25.51 +/- 0.77 in high myopia as the variance ratio [V.R.]=35.226 and P<0.001. The axial length and refraction had a significant negative correlation [r=-0.316 and P<0.05] in mild myopia. More stronger in moderate myopia [r=-0.428 and P<0.001] and strongest in high myopia [r=-0.667 and P<0.001]. The anterior chamber depth and lens thickness showed non-significant correlation with the different degrees of myopia. It was concluded that the axial length was the most influencing factor on refraction as by multiple regression the predicted refraction can be computed by the following equation: predicted refraction = -1.34672 [axial length] + 29.35439


Subject(s)
Humans , Male , Female , Myopia/diagnostic imaging , Refractive Errors , Refractometry/methods , Biometry/methods
15.
Article in English | IMSEAR | ID: sea-91035

ABSTRACT

Quantitative estimation of proteinuria done by the refractometric method was compared with that done by the sulphosalycilic acid method and biuret method in 102 urine samples. The analysis of results by students' t test showed no statistically significant difference between the three methods. It is concluded that quantitative estimation of urinary protein excretion by refractometric method is a simple cheap and reliable method and can be performed easily in the outpatient clinic. The instrument is quite handy and can be carried in the pocket.


Subject(s)
Biuret Reaction , Humans , Proteinuria/diagnosis , Refractometry/methods , Salicylates/chemistry
16.
Assiut Medical Journal. 1990; 14 (3): 13-8
in English | IMEMR | ID: emr-15422

ABSTRACT

This study was carried out in 600 patients [1200 eyes], 434 were males [868 eyes], and 166 were females [332 eyes]. They were of different nationalities attending the out patient eye clinic in the Royal Commission Hospital in Yanbu El-Sinayeia Saudi Arabia complaining subjected to automated refractometry using "Topcon Rm-A6000" computerized refractometer. In about 97% of cases a visual acuity of 6/6 was obtained in our patients. The results of different types of refractive errors were tabulated and compared with similar findings done by various authors using the computerized technique


Subject(s)
Refractometry/methods , Eye
SELECTION OF CITATIONS
SEARCH DETAIL